Insulation & Earth Resistance Tester

  • GDF-5000 Online Insulation Monitoring Device for DC System

    GDF-5000 Online Insulation Monitoring Device for DC System

    GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance.

     

  • GDHX-9500B High Accuracy Phase Detector for Electrical Systems

    GDHX-9500B High Accuracy Phase Detector for Electrical Systems

    GDHX-9500B Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection,  phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.

  • GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester

    GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester

    GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance.

  • GD3128 Series Insulation Resistance Tester

    GD3128 Series Insulation Resistance Tester

    GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. 

  • GDCR1800A   Wireless High Voltage Detector

    GDCR1800A Wireless High Voltage Detector

    GDCR1800 series wireless high voltage tester (with voltage and current indication) is specially designed and manufactured for high voltage transmission line inspection, high voltage transmission line to ground voltage, induced voltage test and current test. This instrument can test the high-voltage to ground at the same time as the alarm of the power check.

    GDCR1800 series wireless high voltage electroscopes have a voltage level of 0.1kV ~ 220kV, which completely covers the power and ground voltage test of each voltage level (3kV, 6.3kV, 10kV, 35kV, 66kV, 110kV, 220kV). which is safe, reliable and saves time. It is an indispensable tool for power transmission line maintenance. During the inspection and maintenance of the transmission line, even if the line has been disconnected, due to the capacitive effect, there may still be very high voltage through induction, which seriously threatens the safety of the operator and the operating process. Make sure the voltage has dropped to a safe and operational voltage level.

  • GDF-3000A DC System Earth Fault Detector

    GDF-3000A DC System Earth Fault Detector

    DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system.

  • GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)

    GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)

    It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.

     

  • GDCR9300 High Precision Wireless Clamp Multimeter for Electrical Testing

    GDCR9300 High Precision Wireless Clamp Multimeter for Electrical Testing

    GDCR9300 Wireless H/L Voltage Hook Type Current Meter break through the traditional structure, specially designed and manufactured for measuring high voltage current, the unique hook type opening mouth structure realizes the unimpeded measurement, and very convenient for field test. The meter is composed of special large-caliber hook type current meter with high voltage insulation rod, equipped with wireless receiver, which can receive the measured data within 100 meters straight line distance, current range: AC 0.00A-9999A. In low voltage lines below 600V, the line current can be measured directly by hook meter without insulation rod.

  • GDCR3000B Digital Earth Resistance Tester

    GDCR3000B Digital Earth Resistance Tester

    GDCR3000B Earth Resistance/Soil Resistivity Tester is special designed for measuring earth resistance, soil resistivity, earth voltage and AC voltage. The latest digital and micro processing technology is adopted, to measure earth resistance by 4-pole, 3-pole or 2-pole.

     

  • GD2000D Insulation Resistance Tester

    GD2000D Insulation Resistance Tester

    GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined.

     

  • GDDT-10U Digital Grounding Down Lead Earth Continuity Tester

    GDDT-10U Digital Grounding Down Lead Earth Continuity Tester

    GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment.

  • GD2000H 10kV Insulation Resistance Tester

    GD2000H 10kV Insulation Resistance Tester

    This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.

12 Next > >> Page 1 / 2

Send your message to us:

Write your message here and send it to us